Magnetrol flow switch pdf

It is recommended that a 50 micron filter be used to protect the internal actuator of the switch. Our market leadership is sustained by a strong ongoing commitment to advance the stateoftheart in level and flow technologies. The force of liquid flow through a valve body and against a flow disc causes it to lift out of the flow path. Fluid components international products flow switches. Products level control flow control volume control software accessories. Find out more about the magnetrol products that will meet your level, flow or interface control challenge. The td1td2 is popular for pump protection, specifically low flow detection with the unique spherical tip design, to prevent pumps from running dry. Magnetrol 910 pdf find great deals for magnetrol echotel ultrasonic level switch a1a0 shop with confidence on ebay ancies to. As the innovator of the first magnetic switch designed for safe, accurate detection of liquid levels, magnetrol has impacted the level instrumentation industry for over 80 years. View and download magnetrol thermatel tg1 installation and operating manual online. Td12d00030 datasheetpdf magnetrol international, inc.

One is the reference and the second is heated to a temperature above the process temperature. Thermatel flowlevel switches should be located to alloweasy access for service. One can find our radar solutions for level and flow measurement at work in petroleum refining, power generation, chemical plants, water and wastewater facilities, pulp and paper mills, and many other process control industries. All magnetrol mechanical level and flow controls are. It is important that all instructions are read carefully and followed in. Magnetrol 910 pdf find great deals for magnetrol echotel ultrasonic level switch a1a0 shop with confidence on ebay ancies to magnetrol.

Magnetrol offers an extensive range of innovative level, flow and volume mganetrol for process industries. Thermatel switches and transmitters utilize the principles of thermal dispersion for accurate and reliable level, flow, and interface control. This pulls the magnet toward the sleeve and actuates the switch. As a level switch, thermatel can be used to detect difference. If the flow rate is critical, an adequate safety margin should be determined. We try our best to ship items the same day payment is made.

Find out more about the magnetrol products that will. To get the best results from the instrument, the instrument should be mounted 20 pipe diameters downstream from any valve, pipe elbow, or other flow disturbance and 10 pipe diameters upstream from any. Magnetrol is committed to providing full customer satisfaction both in quality products and quality service. Vane actuated model f10 switches are used on gas or liquid. Disc actuated model f50 switches are inline type used. Thermatel tg1 measuring instruments pdf manual download. In addition to generalpurpose models, the model fs10a is specifically designed for. Magnetrol offers an extensive range of innovative level, flow and volume controls for process industries. You are bidding on a magnetrol xb154h3bdlm displacer liquid level switch nib. Magnetrols intelligent, reliable and easytouse level controls and flow controls transform industrial processes to improve operational safety and efficiency. The float lever pivoted within the body moves when the process liquid displaces the float. As the flow rate increases, the temperature difference between the sensors decreases.

Thermal dispersion flowlevel switch, td12d00030 datasheet, td12d00030 circuit, td12d00030 data sheet. It is importantthat all instructions are read carefully and followed insequence. Operators are searching for the peace of mind that comes from magbetrol instruments. The quickstart installation instructions are abrief guide to the sequence of steps for experienced technicians. The thermatel td2 switch can easily be adjusted to detect flow gases and liquids, level or liquid. This advanced switch uses pulsed signal technology for superior performance in difficult process conditions, and to provide excellent immunity from sources of electrical noise interference. Paddle flow switches or vane sensors with an electrical contact output are at a specific flow rate. Vaneactuated model f10 switches are used on gas or liquid flow applications in 2 or larger line sizes. Performance and quality matter in the process industries. All magnetrol mechanical level and flow controls are war. Items that are being shipped overnight or any other expedited shipments will. Magnetrol started a legacy of worldclass, awardwinning radar instrumentation, which continues today with the launch of the breakthrough eclipse model 706 guided wave. Magnetrol makes no warranty with respect to the accuracy of the information in this manual.

The thermatel flow switch can be ordered factory calibrated to. The thermatel model td1td2 switch is utilized in flow, level and interface applications. Thermatel detects heat transfer which reduces the temperature difference between the sensors. Magnetrol offers an extensive range of innovative flow controls for process industries. Units may be mounted in any position or orientation. Magnetrol offers an extensive range of innovative level controls and intelligent flow controls for process industries. The ta2 is available with both insertion probes, as well as flow body design for smaller pipe sizes.

During operation the electronicsshould not be exposed to ambient temperature above. Magnetrol echotel installation and operating manual pdf download. The f10 flow switch should be located in a horizontally run pipe with the arrow on the. Displacer level displacer level switch displacer level switch advantages displacer level switch applications displacer level switch calibration displacer level switch disadvantages displacer level switch magnetrol displacer level switch operation displacer level switch pdf displacer level switch price list displacer level switch principle. Flt93 installation, operation and troubleshooting guide preinstallation a. Models f10 and f50 installation and operating manual.

Operation is simple and dependable with no mechanical linkage as the level switch is magnetically actuated. The water flow switch option wfs is a piston activated, inline flow switch which requires filtering of the cooling system water to insure proper operation and long product life. Model f10 switches are vane actuated for use on gas or liquid flow applications in 2 inch or larger line sizes. Magnetrol flow switches are highly reliable flow control solutions utilized to sense the presence or absence of flow in horizontal pipelines. Power supply ground should be connected to the green. Thermatel thermal dispersion flow and level switches. The model f50 control is a globe valve type flow switch designed for installation in. Continuous diagnostics with fault indication, temperature compensation and fast response time make the td1td2 the latest in thermal dispersion technology. Click on the product category below or use the filters at the left to find the magnetrol products that will meet your flow control challenge.

The tk1 liquid level switches are floatactuated devices designed for horizontal mounting in a tank or process vessel through threaded or flanged connections. Continuous diagnostics with fault indication, temperature compensation and fast response time make the td1td2 the latest in thermal. This lowcost switch is ideal for oem applications where a single point high or low level alarm is desired. Learn more about interface magnftrol measurement for separator boots in this blog post. View and download magnetrol thermatel td1 installation and operating manual online. Magnetrol, alldatasheet, datasheet, datasheet search site for electronic components and semiconductors, integrated circuits, diodes, triacs, and other semiconductors. Today magnetrol products serve industries in over 100 countries. Magnetrol flow switches are highly reliable devices utilized to sense the start or stop of flow in horizontal pipelines containing oil and petroleum derivatives, chemicals, water, or air.

Grid controls product line includes flow switches and specialized valves developed for the spa, rural waterwell, water treatment, and aqua culture industries. Actuatorsensorinterface asinterface ultrasonic level switch 12 pages. Jacobs and associates is a leading manufacturer and distributor of industrial instrumentation and controls serving all major industrial markets including power generation, chemical, pulp and paper, oil and natural gas production, water and nuclear. The td1 is a 24 v dc line powered unit with integral electronics and a builtin dpdt relay. They utilize the magnetrol magnetic principle to assure dependable performance. Because process environments are so diverse, magnetrol has created. Depending on the model, alarms trippoints are field configurable for flow, temperature, high or low, hysteresis, time delay and more.

Applications include proof of boiler flow, air conditioning, controlling of dampers according to flow, and protecting pumps, motors and other equipment against low or no flow. Fst200 series thermal dispersion flow switches for. If it is necessary to limit flow to a certain maximum value, the flow control option can be added to most magnatrol valves provided they are not equipped with any other bottom mounted option. The magnetrol quality assurance system is registered to iso 9001 affirming its commitment to known international quality standards providing the strongest assurance of product and service quality available. Thermal dispersion flow, level, interface switch 28 pages. Magnetrol thermal dispersion flow meter model ta2 davis. Magnetrol echotel 961962 ultrasonic level switches.

Omega fst200 series flow switches use thermal dispersion technology to create a very accurate and economical method of sensing flow. Magnetrol logo the customers first call when performance matters. For use as a flow switch, thermatel can be used to detect either a high flow or a low flow condition for both gases and liquids. As the innovator of the first magnetic liquid level switch and pioneer of todays level and flow technology breakthroughs, magnetrol manufactures instrumentation that is more intelligent, more reliable and simpler to install and operate making it far more. Flt93 installation, operation and troubleshooting guide. Force of liquid or gas flow against a vertical flow vane mounted in a line causes the vane to pivot to a horizontal position, moving an attraction sleeve into the field of a switch magnet.

Magnetrol j52 refrigerant level switches description the magnetrol model j52 refrigerant level switches are float actuated units designed for use on liquids with 0. Magnetrol xb154h3bdlm displacer liquid level switch nib. The f10 is a vane type flow switch designed to be installed in 2 through 30 horizontal pipeline by. The eclipse model guided wave radar transmitter offers enhanced reliability, eclipse gwr can be utilized to detect overall level or interface level, and.

Model ta2 thermal mass flow transmitter, based on thermal dispersion technology, provides reliable mass measurement for air and gas flow applications the powerful, yet easytouse, electronics are contained in a compact explosionproof enclosure. Push buttons for manual testing of alarm and error signals. The quickstart installation instructions are abrief guide to the sequence of steps for experienced technicians to follow when installing the. Flowswitches and valve manufacturer for the spa and water management industry.